Nitrogen injection system transformer valve scribd. Works on the principle of arresting chain reaction. Nitrogen injection fire protection system designed for oil filled transformers shall prevent tank explosion and the fire during internal faults resulting in an arc, where tank explosion will normally take few seconds after arc generation and also extinguish the external oil fires on transformer top cover due to tank explosion and for external failures like bushing fires, oltc fires and fire. Nitrogen fire suppression system kidde fire systems. Nitrogen injection fire protection system shall be designed to.
Tank protection systems based on rupture discs and nitrogen injection80. Oildischarge and nitrogen injection fire extinguishing. Nitrogen injection fire protection system manufacturer. Tri parulex fire protection system nitrogen injection. China nitrogen injection fire protection system for transformer. This volume entitled, facilities instructions, standards, and techniques fist, volume 332, transformer fire protection, includes a discussion of this alternative. Nitrogen injection fire protection system on site gas. Nitrogen injection based power transformer fire protection system for transformer protection. Due to the long period required for repair or replacement of transformers, a major goal of the transformer protection is limiting the damage to a faulted transformer.
Scope this volume outlines basic considerations and requirements for fire protection of large, mineraloilfilled, gsu transformers at reclamation powerplants. Inject nitrogen gas to the transformer to move any insulating oil, then drain the oil. China nitrogen injection fire protection system, transformer protector, find details about china nitrogen injection fire protection syste, transformer explosion prevention from nitrogen injection fire protection system, transformer protector baoding mingrui optoelectronic technology co. Also know about fire and safety system installation and its working procedure. Nitrogen injection fire prevention system for 3 nos.
However, detail information concerning ct and voltage transformer vt. Two decades experience on nitrogen injection based explosion prevention and fire extinguishing system 23 cigre 537, guide for transformer fire safety practices a2. Hrishikesh patil senior installation and commissioning engineer ctr manufacturing industry ltd pune. Introduction power transformers figure 1 are a critical and expensive component of the power system. Nitrogen injection fire prevention system for oil filled transformers. Prevents explosion and consequent fire in a power, distribution, generator and rectifier transformer. Nitrogen injection fire protection system installation for. System operation at 110 vdc or 220 vdc or auxiliary. We are providing our clients a wide range of nitrogen injection fire protection system specifications. Blog installation of transformer protector in lithuania. Pressure monitoring switch for backup protection for nitrogen release as redundancy to first signal of oil draining commencement for nitrogen release shall be provided. Agency for oil spill response equipment and security systems.
The oildischarge nitrogen injection fire extinguishing system device consists of four subsystems. We are a well reputed iso 9001 2015 organization engaged in manufacturing, supplying, exporting and installation of fire hydrant, sprinkler system, mvws, hvws system, transformer fire protection nitrogen injection system, fire alarm conventional addressable, gas suppression system fm200, inergen, novec, argonite, co2 gas suppression system, fire tenders water, foam, dcp and multi. Then nitrogen gas is continuously injected, the large. Facilities instructions, standards, and techniques volume. It is safe for use in occupied spaces and poses no threat to the environment. Nitrogen injection fire protection system shall be designed to prevent explosion of transformer tank and the fire during internal faults resulting from arc and also to extinguish the external oil fires on transformer reactor due to tank explosion andor external failures like bushing fires, oltc fires and fire from surrounding equipments, etc. Make sure that the grounding system of the transformer is in perfect conditions. The system can be installed while the tank is in service. Nitrogen injection fire prevention system for oil filled. Substation transformer nitrogen injection fire prevention system. Nitrogen injection fire protection system for oil filled.
System integrator for skid mounted foam based fire extinguishing system. We offer nitrogen injection system for transformer to help prevent oxidation which reduces corrosion and to maintain an inert gas atmosphere in the space above the oil to keep any combustible fro exploding in an oxygen rich environment. The system can extinguishing the fire immediately thro injected the n2 gas into the transformer tank. Transformer protection system manufacturer,transformer. Oildischarge and nitrogen injection fire extinguishing system for. Nitrogen and argon injection fire protection system, nitrogen injection fire protection system,fast depersonalization system, transformer explosion, transformer, transformer explosion and fire,prevention, transformer explosion and fire prevention,robin singh director. Nitrogen injection fire protection system for transformer. Sergi transformer protector, fast depressurization system. Electrical engineering department organised guest lecture on nitrogen injection fire protection system installation for power transformer by mr. Install all the necessary protection against corrosion and mechanical. In the oil filled power transformer oil act both as insulating and cooling media. Saves the transformer from extensive damage apart from ensuring no danger to neighbouring equipments.
Nitrogen injection fire protection systemnifpsn2fs. Xuming power was established in 2003, strong brand in production nitrogen injection fire prevention system for substation. Two decades experience on nitrogen injection based. How transformer nitrogen injection fire protection system.
It is one of the automatic firefighting facilities for fireproof, explosionproof and firefighting of oilimmersed power transformers. Till date more than 5000mva of transformers of ratings as large as 315mva in voltage class upto 400 kv have been saved from explosion and fire under. Magnetization and primary injection test of current transformer for protective relaying jacob tsado 2 general lack of even the most elementary knowledge concerning their performance characteristics and limitations among engineers who are continually using them 1, 2. As a result, bpzmmrd nitrogen injection system is operated and the oil drain valve opens to draw off oil. Some manufactures of transformer fire extinguishing systems, have used nitrogen for injection into the base of oil filled transformers to extinguishing a fire burning from the oil surface. Magnetization and primary injection test of current. Nitrogen is being injected and the fire possibility is fully eliminated. For transformers of high rated power and voltages above 123 kv is usual to provide a fire protection system, using water spray fixed systems, commonly called transformer deluge or fire water systems, as shown in figure 1. Problems with the use of traditional technologies when they are protected, most high voltage power transformers are with a deluge sprinkler system and designers use nfpa15 as a guide to design a system that will cool off the transformer and eventually, extinguish the fire. Nitrogen is an environmentally acceptable, people friendly inert gas fire suppression agent for vital facilities with a wide range of hazards. Transformer explosion prevention and fire extinguishing system. Transformers nitrogen injection system for protection against the transformer explosion for 2 kv transformers 1016 mva, including all required civil works of oil sump, foundations, and any other required for satisfactory working of system. Manufacturers of nitrogen injection explosion prevention system for all sizes of oil filled transformers. Rim seal fire protection system for petroleum storage tankfloating roofs.
At least 2 sets of the system shall be in successful operation for a minimum period of the 2 years. Fire protection system rim seal fire protection system. Since these transformers are oil filled, it is most likely that the fire starts. The modern sergi firefighting system uses a nitrogen injection system. Figure 1 shows a pictorial view of nitrogen injection system installed at power transformer. Nitrogen injection based transformer fire protection. The nitrogen can be injected continuously for 30 mins to stir and cool down the transformer oil, which also isolated the air from the tank. Nitrogen injection fire protection system nifps is a fire protection system which prevent oil tank explosion or rupture and possible oil fire in event of minor nature of arcing due to internal faults in oil filled power transformer.
How transformer nitrogen injection fire protection system work. Therefore, pipelines, cubicles, valves and other components. Characteristics of bpzmmrd nitrogen injection system. Grounding system make sure that the grounding system of the transformer is in perfect conditions. Basics, maintenance, and diagnostics vi contents continued page 2.
Nitrogen injection fire protection system, transformer. Know the working of fire protection and transformer fire prevention system. It should have a fire extinguishing cubicle fec placed on. Pressure monitoring switch for backup protection for nitrogen release as redundancy to first signal of oil draining commencement for nitrogen release shall be. More than 3000 systems in operation in over 20 countries in europe, south america, central america and southeast asia. Nitrogen is a cost effective way to displace oxygen which will result in creating an inert atmosphere. Since these transformers are oil filled, it is most likely that the fire starts from the bottom of. Nitrogen injection fire protection system designed for oil filled transformers shall prevent tank explosion and the. Technical specification singareni collieries company. Rim seal fire protection system is designed to automatically detect and extinguish the fire at the incipient stage. Nitrogen injection system free download as word doc. On the ground floor 11kv electrical substation is to be erected. The system shall be designed to be operated manually in case of failure of power supply to the system.
Nitrogen injection fire protection, fire protection system for transformer, nitrogen injection manufacturer supplier in china, offering nitrogen injection fire protection system for transformer, nice quality protective face shield, rubber nitrile pvc disposable gloves and so on. System shall have interlock to ensure operation of system only after transformer electrical isolation to avoid nitrogen injection in energized transformer. The transformer protector tp complies with the nfpa recommandation of fast depressurization systems for all power plants and substations transformers, under the code 850. Working of fire protection and prevention system nifps. Manufactured in accordance with the international quality benchmarks, these nitrogen injection fire protection system are suitable for outdoor indoor installations and can also be operated in the absence of power. The system shall have been in successful operation commissioned in indian abroad installations for at least last five years for protection of transformers of 220 kv and higher voltage class. Scada compatible system suitable for iecdnp protocol available on request. Nitrogen injection system for transformer sakthi fire. On sites nitrogen generators are used around the world for fire protection in explosive atmospheres. Enjoy the videos and music you love, upload original content, and share it all with friends, family, and the world on youtube. An inert atmosphere will not allow combustion thus will either suppress or prevent a fire or explosion.
Nitrogen injection system for transformer protection. General description nitrogen injection system should be a dedicated system for each oil filled transformer reactor. Each oil filled transformer shall be provided with a dedicated nitrogen. As per standard code, the components of this system are shown by red color. Product description we are bringing forth our customers a broad spectrum of transformer protection system that is approved by fire authorities and tariff advisory committee tac. What is the application of nitrogen injection system in. Nitrogen injection fire protection system designed for oil filled transformers shall. Nitrogen fire suppression systems utilize pure nitrogen, which is naturally occurring inert gas present in the atmosphere. Nitrogen injection fire protection system for power transformers having capacity 10 mva or.